Ahmedabad, Gujarat
GST No. 24APUPS9459Q1ZE
Approx. Rs 35 / PieceGet Latest Price
Product Details:| Minimum Order Quantity | 100 Piece |
| Sprinkler Type | Pendent |
| Type | Spray Head |
| Response Type | Standard Response |
| K Factor | K57 |
| Material | Stainless Stee |
| Temperature Rating | 0-120 deg C |
| Usage/Application | Fire Sprinkler |
| Country of Origin | Made in India |
| Surface Finishing | Chrome Coated |
Fire sprinklers are the most effective way to control a fire in its early stages.1 Their "usage" goes beyond just spraying water; they are strategic tools tailored to specific environments.2
+1
Using stainless steel corrugated hoses (flexible drops) has become the modern standard for installing these heads because they allow for precise positioning in ceiling tiles and provide better durability during earthquakes.
1. Common Usages by Environment| Environment | System Type | Purpose of Usage |
| Offices & Schools | Wet Pipe | Fastest response. Water is always in the pipes, ready for immediate discharge. |
| Parking Garages | Dry Pipe | Usage in unheated areas. Pipes are filled with pressurized air so they don't freeze and burst. |
| Data Centers | Pre-Action | Two-step activation. Requires both a smoke detector AND heat to trigger, preventing accidental water damage to servers. |
| Chemical Plants | Deluge | High-hazard usage. All heads spray simultaneously to "flood" a high-risk area instantly. |
| Residential | Home Systems | Life safety. Designed to activate faster than industrial heads to give families time to escape. |
Life Safety: Sprinklers reduce the risk of dying in a fire by 87%.3 They keep exit paths clear of smoke and heat.4
+1
Property Conservation: They contain 96% of fires to the room where they started.5
Water Efficiency: A sprinkler head uses roughly 10 to 25 gallons of water per minute. In contrast, a firefighter's hose uses over 100 gallons per minute—meaning sprinklers actually cause less water damage than the alternative.6
Insurance Discounts: Most commercial and residential insurers offer 5% to 15% discounts on premiums for buildings with active systems.
To ensure the system actually works when needed, follow these usage rules:
The 18-inch Rule: Never stack boxes or furniture within 18 inches of a sprinkler head.7 It blocks the spray pattern (the "deflector").
No Hanging Items: Never hang clothes, decorations, or wiring from the sprinkler heads or the stainless steel flexible hoses. This can cause accidental activation or structural failure.
Temperature Sensitivity: Ensure you aren't using a "low-temp" head (Red bulb) near a high-heat source like an industrial oven, or it will trigger without a fire.
Additional Information:
Approx. Rs 55 / PieceGet Latest Price
Product Details:| Minimum Order Quantity | 50 Piece |
| Sprinkler Type | Pendent |
| Type | Spray Head |
| Response Type | Extended Coverage |
| K Factor | K57 |
| Material | Stainless Steel |
| Mounting Type | Ceiling Mounted |
| Temperature Rating | 120 deg C |
| Finishing | Chrome Coated |
| Country of Origin | Made in India |
Fire sprinklers are the most effective way to control a fire in its early stages.1 Their "usage" goes beyond just spraying water; they are strategic tools tailored to specific environments.2
+1
Using stainless steel corrugated hoses (flexible drops) has become the modern standard for installing these heads because they allow for precise positioning in ceiling tiles and provide better durability during earthquakes.
1. Common Usages by Environment| Environment | System Type | Purpose of Usage |
| Offices & Schools | Wet Pipe | Fastest response. Water is always in the pipes, ready for immediate discharge. |
| Parking Garages | Dry Pipe | Usage in unheated areas. Pipes are filled with pressurized air so they don't freeze and burst. |
| Data Centers | Pre-Action | Two-step activation. Requires both a smoke detector AND heat to trigger, preventing accidental water damage to servers. |
| Chemical Plants | Deluge | High-hazard usage. All heads spray simultaneously to "flood" a high-risk area instantly. |
| Residential | Home Systems | Life safety. Designed to activate faster than industrial heads to give families time to escape. |
Life Safety: Sprinklers reduce the risk of dying in a fire by 87%.3 They keep exit paths clear of smoke and heat.4
+1
Property Conservation: They contain 96% of fires to the room where they started.5
Water Efficiency: A sprinkler head uses roughly 10 to 25 gallons of water per minute. In contrast, a firefighter's hose uses over 100 gallons per minute—meaning sprinklers actually cause less water damage than the alternative.6
Insurance Discounts: Most commercial and residential insurers offer 5% to 15% discounts on premiums for buildings with active systems.
To ensure the system actually works when needed, follow these usage rules:
The 18-inch Rule: Never stack boxes or furniture within 18 inches of a sprinkler head.7 It blocks the spray pattern (the "deflector").
No Hanging Items: Never hang clothes, decorations, or wiring from the sprinkler heads or the stainless steel flexible hoses. This can cause accidental activation or structural failure.
Temperature Sensitivity: Ensure you aren't using a "low-temp" head (Red bulb) near a high-heat source like an industrial oven, or it will trigger without a fire.
Additional Information:
Approx. Rs 80 / PieceGet Latest Price
Product Details:| Temperature Rating | 68 C |
| Response Type | Standard Response |
| K Factor | K115 |
| Brand | Bright |
| Connection Size | 1/2 inch |
| Spray Pattern | Standard Coverage |
| Material | Available Stainless Steel, Brass |
| Usage/Application | Fire Safety |
| Bulb Size | 3 mm |
| Finish | Brass |
| Approval | UL and FM, VdS, UL, CE, FM |
| Connecting Thread | 1/2" or 3/4" or 1" |
| Working Pressure | 1.2 MPa |
Approx. Rs 2,500 / PieceGet Latest Price
Product Details:| Minimum Order Quantity | 258 Piece |
| Brand | Standalone |
| Sensor Type | Photoelectric Smoke Detector |
| Operating Temperature | -10DegreeC to 50DegreeC |
| Alarm Sensor Type | Ionization |
| Usage/Application | Office Buildings |
| Power Source | 12 W |
| Color | White |
A Smoke Detector is a critical life-safety device designed to sense the presence of smoke—an early indicator of fire—and provide an audible or visual warning. It allows occupants time to evacuate before a fire spreads or toxic smoke levels become lethal.
🔍 Core TechnologiesModern detectors typically use one of two primary sensing methods (or a combination of both):
Photoelectric (Optical): Uses a light source and a sensor. When smoke particles enter the chamber, they scatter the light onto the sensor, triggering the alarm.
Best for: Slow, smoldering fires (e.g., a cigarette on a sofa).
Advantage: Fewer false alarms from cooking steam.
Ionization: Uses a tiny amount of radioactive material to ionize the air between two charged plates. Smoke particles disrupt this flow of ions, triggering the alarm.
Best for: Fast-flaming fires (e.g., grease fires or paper).
Advantage: Highly sensitive to tiny, invisible smoke particles.
Dual-Sensor: Combines both technologies into one unit for the most comprehensive protection.
| Type | Description |
| Battery-Powered | Standalone units running on 9V or long-life 10-year lithium batteries. Easy to install. |
| Hardwired | Connected directly to the building's electrical system. Usually includes a battery backup for power outages. |
| Interconnected | If one alarm detects smoke, all alarms in the building sound simultaneously. Essential for multi-story homes. |
| Smart Detectors | Connects to Wi-Fi to send alerts directly to your smartphone if you are away from home. |
Ceiling Mount: Since smoke rises, detectors should be placed in the center of the ceiling.
Walls: If wall-mounted, they should be 10–30 cm (4–12 inches) below the ceiling.
Essential Locations: * Inside every bedroom.
Outside every sleeping area (hallways).
On every level of the home (including the basement).
Avoid: Placing them too close to kitchens (false alarms) or near air vents/windows (drafts can push smoke away from the sensor).
Approx. Rs 1,800 / PieceGet Latest Price
Product Details:| Usage/Application | Fire Fighting |
| Diameter | 50-75 mm |
| Reel Length | 10 m |
| Color | Red |
| Pressure | 1.0 MPa, 1.3 MPa |
Approx. Rs 100 / PieceGet Latest Price
Product Details:| Material | SS |
| Size | 3/4 inch |
| Usage/Application | Gas Pipe |
| Size/Diameter | 1 inch |
| Surface Treatment | Coated |
| Maximum Working Pressure | 40bar |
| Packaging Type | Box |
Approx. Rs 5,000 / PieceGet Latest Price
Product Details:| Diameter | 50mm |
| Reel Length | 10 m |
| Brand | Zeca |
| Usage/Application | water |
| Material | hose reel |
| Pressure | 1.0 MPa |
| Drum Diameter | 50mm |
| Temperature | -20+120 |
| Tube Length | 10 mtr-30 mtr |
| Surface Finishing | smooth |
Approx. Rs 150 / PieceGet Latest Price
Product Details:| Minimum Order Quantity | 24 Piece |
| Valve Type | Ball Valve |
| Valve Size | 1"-8" |
| Pressure Rating | 1000 WOG |
| End Connection | Flanged |
| Pressure | Low Pressure |
| Usage/Application | Water |
| Brand | Rexroth |
| Material | Stainless Steel |
| Medium | Water |
| Standards | API 600 |
| Country of Origin | Made in India |
Additional Information:
Approx. Rs 115 / PieceGet Latest Price
Product Details:| Minimum Order Quantity | 50 Piece |
| Material | Stainless Steel |
| Mounting Type | Wall Mounted |
| Style | Pendent |
| Body Material | Brass |
| Thread Size | 1/2 inch |
| Country of Origin | Made in India |
Additional Information:
Approx. Rs 130 / MeterGet Latest Price
Product Details:| Minimum Order Quantity | 1000 Meter |
| Reel length | 20 m |
| Material | PU |
| Diameter | 63 mm |
| Usage/Application | Industrial |
| Packaging Type | Roll |
| Brand | Force |
| Hose Color | Red |
| Pressure | 1.0 MPa |
Approx. Rs 1,000 / PieceGet Latest Price
Product Details:| Material | Stainless Steel |
| Product Type | Double Door |
| Usage/Application | Fire Safety |
| Diameter | 50mm |
| Is It Rust Proof | Rust Proof |
| Surface Treatment | Galvanised |
Approx. Rs 90 / PieceGet Latest Price
Product Details:| Minimum Order Quantity | 1580 Piece |
| Material | Brass |
| Mounting Type | Wall Mounted |
| Color | Silver |
| Features | High |
| Usage/Application | Industry |
| Style | Upright |
Approx. Rs 1,800 / PieceGet Latest Price
Product Details:| Type | A type |
| Packaging Type | Roll |
| Diameter | 63 mm |
| Hose Color | Red |
| Material | PU |
| Country of Origin | Made in India |
| Usage/Application | Industrial |
Approx. Rs 50 / PieceGet Latest Price
Product Details:| Minimum Order Quantity | 1247 Piece |
| Sign Message | Fire Extinguisher |
| Sign Material | Vinyl Sticker |
| Sign Size | 150 x 200 mm |
| Color | Red |
| Shape | Rectangular |
| Material | PVC |
| Thickness | 1.50-10 mm |
| Country of Origin | Made in India |
A Fire Extinguisher Sign is a critical safety marker used to identify the location of fire-fighting equipment and provide essential instructions on its use. In emergency situations where visibility may be low or panic may occur, these signs act as immediate visual guides to ensure a rapid response.
🎨 Visual CharacteristicsStandard Colors: In accordance with international standards (ISO 7010 / OSHA / BS EN ISO 7010), fire equipment signs use a Signal Red background with White text or pictograms. Red is used globally to denote "Danger" and "Fire Fighting Equipment."
Pictogram: A universal white icon of a fire extinguisher. Some signs also include an arrow pointing down or toward the equipment.
Material Options:
Rigid Plastic (PVC): Durable for indoor use.
Photoluminescent (Glow-in-the-Dark): Highly recommended; these signs remain visible during power outages or in smoke-filled environments.
Self-Adhesive Vinyl: For easy application on smooth surfaces or cabinets.
These are large signs mounted high (usually 2 meters or more) to be seen from a distance or across a large room.
Flat: Mounted against the wall.
3D / Projecting: Triangle-shaped signs that stick out from the wall so they can be seen from both directions in a long corridor.
Placed directly above the extinguisher, these provide technical details:
Extinguisher Type: (e.g., Water, Foam, $CO_2$, Powder).
Classes of Fire: Symbols showing which fires the unit is safe for (e.g., Class A for wood/paper, Class C for electrical).
Usage Instructions: Often includes the PASS method (Pull, Aim, Squeeze, Sweep).
Height: Location signs should be mounted no less than 2.0m from the floor to avoid being blocked by furniture or people. ID signs are typically mounted at eye level (1.5m to 1.8m).
Accessibility: Signs must not be obstructed by doors or storage.
Tactile/Braille: In many public buildings (ADA compliance), signs must include raised characters and Braille for the visually impaired.
| Extinguisher Type | Sign Identification Color | Best For |
| Water | Solid Red | Wood, paper, textiles. |
| Foam | Cream | Flammable liquids (petrol/oil). |
| $CO_2$ | Black | Electrical fires & liquids. |
| Dry Powder | Blue | Multi-purpose (A, B, and C). |
| Wet Chemical | Yellow | Cooking oils and fats. |
Additional Information:
Approx. Rs 30 / PieceGet Latest Price
Product Details:| Size | .2-.5 |
| Material | Brass |
| Usage/Application | Agriculture |
| Pressure | 7-10 bar |
| Country of Origin | Made in India |
Mist and fogging nozzles are precision devices designed to atomize liquid into microscopic droplets. While the terms are often used interchangeably, they represent a spectrum of "fineness" based on droplet size (measured in microns, $\mu m$).
1. Mist vs. Fog: The Micron ScaleThe primary difference between a "mist" and a "fog" is how the droplets behave in the air.
| Type | Droplet Size | Behavior | Typical Application |
| Mist | $30 - 60 \mu m$ | Falls slowly; can cause slight dampness. | Outdoor patio cooling, greenhouses. |
| Wet Fog | $20 - 30 \mu m$ | Suspends briefly; evaporates quickly. | Industrial humidification, dust suppression. |
| Dry Fog | $< 20 \mu m$ | Floats like a cloud; stays dry to the touch. | Cleanrooms, special effects, delicate indoor cooling. |
There are three main designs used to break water into such tiny particles:
Small Orifice (Pressure Swirl): The most common type. Water is forced through a tiny hole (as small as $0.1$ mm). Internal vanes spin the water rapidly so it "shatters" into droplets as it exits.
Impingement (Pin Nozzle): A high-velocity stream of water hits a small "target" pin located directly in front of the orifice. The impact shears the water into an ultra-fine spray.
Air Atomizing (Pneumatic): These use compressed air to "rip" the water apart. They can produce the finest "dry fog" even at low water pressures.
The performance of a nozzle is heavily dependent on the pump pressure driving it.
Low Pressure ($10 - 250$ psi): Usually made of brass. These are common for residential patio kits. They produce larger droplets that may feel "wet."
High Pressure ($250 - 1500$ psi): Usually made of Stainless Steel or have Ceramic/Ruby inserts. These are required for "flash evaporation" (cooling the air without getting people wet).
Anti-Drip Features: High-quality nozzles contain a spring-loaded check valve. This ensures the nozzle snaps shut the moment the pump stops, preventing messy "dripping" onto floors or furniture.
Because the holes are so small, clogging is the #1 cause of failure.
Filtration: A $5$ or $10$-micron water filter is mandatory before the pump.
Hard Water: Calcium buildup (scale) will distort the spray pattern. Look for "cleanable" nozzles where the internal impeller can be removed and soaked in a descaling solution (like vinegar).
0.15 mm (Yellow): Ultra-fine; used for indoor humidification.
0.30 mm (Black): The "industry standard" for outdoor cooling and patios.
0.50 mm (Green): Higher flow; used for dust suppression or animal cooling in barns.
Would you like me to help you calculate how many nozzles you need for a specific area, or are you looking for a recommendation on a specific pump pressure for your project?
Approx. Rs 800 / PieceGet Latest Price
Product Details:| Minimum Order Quantity | 128 Piece |
| Usage/Application | Fire Fighting |
| Diameter | 50-65 mm |
| Coating | Color Coated |
| Packaging Type | Roll |
| Reel Length | 30 m |
| Hose Color | Red |
| Max Cable Length | >25 m |
| Pressure | 1.0 MPa |
A Fire Hose Reel is a critical component of a fire safety system, designed to provide a ready supply of water to help extinguish fires, particularly in their early stages. It consists of a hose mounted on a reel, typically located in areas where fires are likely to occur, such as in commercial buildings, warehouses, hospitals, schools, or industrial facilities. Fire hose reels are an essential tool for controlling small fires before they escalate, and they are often strategically placed near exits or fire exits for quick access.
Approx. Rs 98 / PieceGet Latest Price
Product Details:| K-FACTOR (Discharge Rate) | 5.6 US (80 metric) |
| Thread Size | 3/4 NPT |
| Mounting Type | Upright |
| Temperature Rating | 120 deg C |
| Working Pressure | 0.1 MPa -- 1.2 Mpa |
| Material | Available Stainless Steel, Brass |
Approx. Rs 150 / PieceGet Latest Price
Product Details:| Brand | T&S |
| Size | All |
| Material | Mild Steel |
| Color | Red and White |
| Usage/Application | For Fire Safety |
| Type | Fire Safety Equipments |
Approx. Rs 1,000 / PieceGet Latest Price
Product Details:| Minimum Order Quantity | 5 Piece |
| Hose length | 8 m |
| Pressure rating | 10 bar |
| Reel Length | 10 m, 30 m, 20 m |
| Type | Spray Hose Pipe |
| Brand | Zeca |
| Hose Size | 3/4 inch, 1/2 inch |
| Unit Length | 30m, 100m, 6m |
| Pressure | 1.3 MPa, 1.0 MPa, 0.8 MPa |
| Drum Diameter | 65mm, 50mm, 80mm |
| Diameter | 3/8",1/4" |
| Nominal Size | 1/2 inch |
| Hose Material | PU Braid Hose |
| Usage | Air Hose Reel |
| Hose Color | Blue |
| Color | Black |
Here is a professional and clean description for a Zypher Hose Reel (suitable for catalog, website, or quotation use):
Zypher Hose Reel – DescriptionA Zypher hose reel is a durable hose management system designed to store, protect, and dispense hoses efficiently in industrial, commercial, and workshop environments. It ensures safe, organized, and tangle-free hose handling, improving workplace safety and operational efficiency.
ConstructionHeavy-duty steel or reinforced metal frame with corrosion-resistant coating
High-quality spring or motor-driven rewind mechanism
Precision swivel joint for smooth hose movement
Robust locking system to hold hose at desired length
Smooth automatic or manual hose rewind
Reduces hose wear, kinking, and damage
Saves floor space and keeps work areas organized
Easy wall, ceiling, or floor mounting options
Designed for long service life under continuous use
Air, water, oil, grease, fuel, or chemical hose management
Industrial workshops and manufacturing plants
Automotive service stations and garages
Construction sites and maintenance areas
✔ Improves safety by preventing hose tangling
✔ Enhances productivity and hose lifespan
✔ Clean and professional workspace appearance
✔ Reliable performance in demanding environments
If you want, I can also provide:
• Short one-line description
• Technical specification format
• Marketing / brochure version
• Customized description with your company name
Just tell me 👍
Additional Information:
Explore More Products
© Jay Tools And Hardware Stores. All Rights Reserved (Terms of Use)
Developed and Managed by IndiaMART InterMESH Limited